| Hydro-Pac,Inc. High-Pressure Hydrogen Compressors Multi-Stage Compressor Capacity in (scfm) - 70 to 140 psi Inlet |
|||||||||||
|
Model Number |
Motor hp |
Inlet Pressure (psig) |
|||||||||
|
70
|
80
|
90
|
100
|
110
|
120
|
130
|
140
|
||||
|
|
|
C1.5-03-70/140LX |
3
|
3.3
|
3.9
|
4.5
|
4.8
|
5.2
|
5.6
|
6.1
|
6.6
|
|
C1.5-05-70/140LX
|
5
|
5.0
|
6.0
|
6.8
|
7.3
|
7.9
|
8.6
|
9.4
|
10.1
|
||
|
C1.5-10-70/140LX
|
10
|
10.1
|
11.9
|
13.6
|
14.6
|
15.8
|
17.2
|
18.8
|
20.3
|
||
|
C1.5-15-70/140LX
|
15
|
15.1
|
17.9
|
20.4
|
21.9
|
23.7
|
25.7
|
28.2
|
30.4
|
||
|
C1.5-20-70/140LX
|
20
|
20.2
|
23.9
|
27.2
|
29.2
|
31.6
|
34.3
|
37.5
|
40.5
|
||
|
C1.5-40-70/140LX
|
40
|
40.4
|
47.7
|
54.5
|
58.5
|
63.1
|
68.6
|
75.1
|
81.1
|
||
|
|
C03-03-70/140LX
|
3
|
2.0
|
2.4
|
2.8
|
2.9
|
3.2
|
3.5
|
3.8
|
4.1
|
|
|
C03-05-70/140LX
|
5
|
3.1
|
3.7
|
4.3
|
4.5
|
4.9
|
5.3
|
5.8
|
6.3
|
||
|
C03-10-70/140LX
|
10
|
6.2
|
7.4
|
8.5
|
9.0
|
9.8
|
10.6
|
11.6
|
12.5
|
||
|
C03-15-70/140LX
|
15
|
9.3
|
11.1
|
12.8
|
13.5
|
14.7
|
15.9
|
17.4
|
18.8
|
||
|
C03-20-70/140LX
|
20
|
12.4
|
14.8
|
17.0
|
18.0
|
19.6
|
21.2
|
23.2
|
25.0
|
||
|
C03-40-70/140LX
|
40
|
24.8
|
29.6
|
34.0
|
36.0
|
39.2
|
42.4
|
46.4
|
50.0
|
||
|
|
C06-03-70/140LX
|
3
|
1.1
|
1.3
|
1.5
|
1.6
|
1.7
|
1.9
|
2.1
|
2.2
|
|
|
C06-05-70/140LX
|
5
|
1.7
|
2.0
|
2.3
|
2.4
|
2.6
|
2.9
|
3.2
|
3.4
|
||
|
C06-10-70/140LX
|
10
|
3.3
|
3.9
|
4.5
|
4.8
|
5.2
|
5.7
|
6.3
|
6.8
|
||
|
C06-15-70/140LX
|
15
|
5.0
|
5.9
|
6.8
|
7.2
|
7.8
|
8.6
|
9.5
|
10.2
|
||
|
C06-20-70/140LX
|
20
|
6.6
|
7.8
|
9.0
|
9.6
|
10.4
|
11.4
|
12.6
|
13.6
|
||
|
C06-40-70/140LX
|
40
|
13.2
|
15.6
|
18.0
|
19.2
|
20.8
|
22.8
|
25.2
|
27.2
|
||
|
Hydro-Pac, Inc. P.O. Box 921 7470 Market Road Fairview, PA 16415 USA 1. The machines listed on this web page represent a portion of our product line. The flexible design of our hydraulically driven intensifiers allows us to customize machine configurations for other operating conditions. Please consult with Hydro-Pac, Inc. for applications not covered by machines listed here. 2. If you need compressors for a specific fueling strategy, we will be happy to help you select the best compressors for that fueling strategy. Please consult the technical staff at Hydro-Pac, Inc. for assistance. 3. All capacities listed are based on hydrogen gas at a maximum inlet temperature of 80ºF (27ºC). The capacity will be less if the temperature of the inlet gas is higher. 4. Charts showing capacities in (scfm), (Nm3/hr) or (kg/day) are available upon request. 5. For short delivery times, Hydro-Pac stocks parts for select models. 6. This information is supplied to reference only and is subject to change. 7. Please consult with the technical staff at Hydro-Pac, Inc. for more detailed information about our products. 8. Hydro-Pac's standard terms and conditions of sale apply to all products 9. Hybrid compressors are usually sized for a specific application. Please consult the technical staff at Hydro-Pac, Inc. for more information about the performance of these machines. Important Notes:Phone: 800-394-1511 Local: 814-474-1511 Fax: 814-474-3421 E-mail: info@hydropac.com |
||