Hydro-Pac,Inc.
High-Pressure Hydrogen Compressors
Multi-Stage Compressor Capacity in (scfm) - 300 to 600 psi Inlet

Model Number

Motor hp

Inlet Pressure (psig)

300
350
400
450
500
550
600
C03-03-300/600LX
3
4.9
5.7
6.5
7.3
8.1
8.8
9.6
C03-05-300/600LX
5
7.6
8.8
10.0
11.1
12.3
13.5
14.7
C03-10-300/600LX
10
15.1
17.5
19.9
22.2
24.6
26.9
29.3
C03-15-300/600LX
15
22.7
26.3
29.9
33.3
36.9
40.4
44.0
C03-20-300/600LX
20
30.2
35.0
39.8
44.4
49.2
53.8
58.6
C03-40-300/600LX
40
60.4
70.0
79.6
88.8
98.4
108
117
C06-03-300/600LX
3
2.9
3.4
3.9
4.4
4.8
5.3
5.8
C06-05-300/600LX
5
4.5
5.2
6.0
6.7
7.4
8.1
8.8
C06-10-300/600LX
10
8.9
10.4
11.9
13.3
14.7
16.2
17.6
C06-15-300/600LX
15
13.4
15.6
17.9
20.0
22.1
24.3
26.4
C06-20-300/600LX
20
17.8
20.8
23.8
26.6
29.4
32.4
35.2
C06-40-300/600LX
40
35.6
41.6
47.6
53.2
58.8
64.8
70.4

Hydro-Pac, Inc. • P.O. Box 921 • 7470 Market Road • Fairview, PA 16415 USA

1. The machines listed on this web page represent a portion of our product line. The flexible design of our hydraulically driven intensifiers allows us to customize machine configurations for other operating conditions. Please consult with Hydro-Pac, Inc. for applications not covered by machines listed here.

2. If you need compressors for a specific fueling strategy, we will be happy to help you select the best compressors for that fueling strategy. Please consult the technical staff at Hydro-Pac, Inc. for assistance.

3. All capacities listed are based on hydrogen gas at a maximum inlet temperature of 80ºF (27ºC). The capacity will be less if the temperature of the inlet gas is higher.

4. Charts showing capacities in (scfm), (Nm3/hr) or (kg/day) are available upon request.

5. For short delivery times, Hydro-Pac stocks parts for select models.

6. This information is supplied to reference only and is subject to change.

7. Please consult with the technical staff at Hydro-Pac, Inc. for more detailed information about our products.

8. Hydro-Pac's standard terms and conditions of sale apply to all products

9. Hybrid compressors are usually sized for a specific application. Please consult the technical staff at Hydro-Pac, Inc. for more information about the performance of these machines.

Important Notes:

Phone: 800-394-1511 • Local: 814-474-1511 • Fax: 814-474-3421 • E-mail: info@hydropac.com